← Back batch 95 of 100 ← Batch 63 Batch 66 →
Experiments / Batch 65

Batch 65 not OK

04.05.2026 · Mr. Mohan Yadav (Completed By); Dr. Sachin Jagtap (Authorized By) · also written as S 9076 · BYK 9076 · 65
Application test
not OK
2 tests
Conclusion — verbatim from the source
“Results: Not OK (Gloss and Re-solubility inferior).”
S 9076 #65 not ok.docx, test report table

No recipe or process data extracted yet.

Sample unspecified sample
not OK Ink Base - Nitrocellulose Polyurethane, Violet 23 (Ink Base - Nitrocellulose Polyurethane) — Gloss and Re-solubility inferior
ParameterThis sampleStandard
Grinding (µm) < 5 µm < 5 µm
Colour Shade As per Std Reference Std
Transparency Opaque Opaque (vs Reference Std)
Color Strength (%) 98-99 98-99 (vs 100.00)
Viscosity (B4 Cup @26°C) 29 s 29 s (vs 21 s)
Adhesion (Tape Test) Pass Pass
Gloss @ 60° 55.9 55.9 (vs 66.4)
Re-solubility (Rating) 2 2 (vs 4)
Separation No No
Settling No No
not OK Ink Base - Nitrocellulose Polyurethane, Violet 27 (Ink Base - Nitrocellulose Polyurethane) — Gloss and Re-solubility inferior
ParameterThis sampleStandard
Grinding (µm) < 5 µm < 5 µm
Colour Shade As per Std Reference Std
Transparency As per Std As per Std
Color Strength (%) 94-95 94-95 (vs 100.00)
Viscosity (B4 Cup @26°C) 21 s 21 s (vs 19 s)
Adhesion (Tape Test) Pass Pass
Gloss @ 60° 9.1 9.1 (vs 7.8)
Re-solubility (Rating) 2 2 (vs 4)
Separation No No
Settling No No
Test report photos
S 9076 #65 not ok.docx — 2 photos
Where this record comes from
S 9076 #65 not ok.docx — application testing
Something wrong on this page? Record a correction
Your correction is permanent: it survives every re-extraction and the field can no longer be changed by the system.
Field-by-field provenance (5 fields) — for auditors
1 extraction fragments · merged 2026-08-25 · 0 human-validated fields
Fix a wrong or missing extraction side-by-side with the original: app-test--S_9076_65_not_ok
FieldSourceExtractorConf.
dateS 9076 #65 not ok.docx document body (test report table) qwen-tasks/extract-fragment.md@unversionedhigh
scientistS 9076 #65 not ok.docx document body (test report table) qwen-tasks/extract-fragment.md@unversionedhigh
conclusionS 9076 #65 not ok.docx document body (test report table) qwen-tasks/extract-fragment.md@unversionedhigh
samples[0]S 9076 #65 not ok.docx document body (test report table) qwen-tasks/extract-fragment.md@unversionedhigh
outcomeS 9076 #65 not ok.docx document body (test report table) qwen-tasks/extract-fragment.md@unversionedhigh
Raw record JSON
{
  "record_id": "exp-9076-065",
  "project": "9076",
  "aliases": [
    "S 9076",
    "BYK 9076",
    "65"
  ],
  "provenance": {
    "fragments": [
      "app-test--S_9076_65_not_ok"
    ],
    "field_provenance": {
      "date": {
        "source_file": "pdf/9076 Data for Raven POC project/Application tetsing Report/S 9076 #65 not ok.docx",
        "extractor": "qwen-tasks/extract-fragment.md",
        "extractor_version": "unversioned",
        "extracted_date": "",
        "locator": "document body (test report table)",
        "human_checked": true
      },
      "scientist": {
        "source_file": "pdf/9076 Data for Raven POC project/Application tetsing Report/S 9076 #65 not ok.docx",
        "extractor": "qwen-tasks/extract-fragment.md",
        "extractor_version": "unversioned",
        "extracted_date": "",
        "locator": "document body (test report table)",
        "human_checked": true
      },
      "conclusion": {
        "source_file": "pdf/9076 Data for Raven POC project/Application tetsing Report/S 9076 #65 not ok.docx",
        "extractor": "qwen-tasks/extract-fragment.md",
        "extractor_version": "unversioned",
        "extracted_date": "",
        "locator": "document body (test report table)",
        "human_checked": true
      },
      "samples[0]": {
        "source_file": "pdf/9076 Data for Raven POC project/Application tetsing Report/S 9076 #65 not ok.docx",
        "extractor": "qwen-tasks/extract-fragment.md",
        "extractor_version": "unversioned",
        "extracted_date": "",
        "locator": "document body (test report table)",
        "human_checked": true
      },
      "outcome": {
        "source_file": "pdf/9076 Data for Raven POC project/Application tetsing Report/S 9076 #65 not ok.docx",
        "extractor": "qwen-tasks/extract-fragment.md",
        "extractor_version": "unversioned",
        "extracted_date": "",
        "locator": "document body (test report table)",
        "human_checked": true
      }
    },
    "last_merged": "2026-08-25"
  },
  "documents": [
    {
      "file": "pdf/9076 Data for Raven POC project/Application tetsing Report/S 9076 #65 not ok.docx",
      "role": "application_test",
      "link_basis": "alias match: S 9076",
      "link_status": "rule"
    }
  ],
  "validation": {
    "validated_fields": {},
    "corrections_applied": []
  },
  "date": "04.05.2026",
  "scientist": "Mr. Mohan Yadav (Completed By); Dr. Sachin Jagtap (Authorized By)",
  "conclusion": "Results: Not OK (Gloss and Re-solubility inferior).",
  "samples": [
    {
      "sample_name": "S 9076",
      "batch_no": "65",
      "nature": "Liquid",
      "colour": "Amber",
      "reference_standard": "BYK 9076",
      "application_tests": [
        {
          "test": "Ink Base - Nitrocellulose Polyurethane, Violet 23",
          "system": "Ink Base - Nitrocellulose Polyurethane",
          "pigment": "Violet 23",
          "reference_standard": "Finalux 108",
          "conditions": "B4 Cup @26°C",
          "result": {
            "Grinding (µm)": "< 5 µm",
            "Colour Shade": "As per Std",
            "Transparency": "Opaque",
            "Color Strength (%)": "98-99",
            "Viscosity (B4 Cup @26°C)": "29 s",
            "Adhesion (Tape Test)": "Pass",
            "Gloss @ 60°": "55.9",
            "Re-solubility (Rating)": "2",
            "Separation": "No",
            "Settling": "No"
          },
          "vs_reference": {
            "Grinding (µm)": "< 5 µm",
            "Colour Shade": "Reference Std",
            "Transparency": "Opaque (vs Reference Std)",
            "Color Strength (%)": "98-99 (vs 100.00)",
            "Viscosity (B4 Cup @26°C)": "29 s (vs 21 s)",
            "Adhesion (Tape Test)": "Pass",
            "Gloss @ 60°": "55.9 (vs 66.4)",
            "Re-solubility (Rating)": "2 (vs 4)",
            "Separation": "No",
            "Settling": "No"
          },
          "verdict": "not ok",
          "failure_reason": "Gloss and Re-solubility inferior"
        },
        {
          "test": "Ink Base - Nitrocellulose Polyurethane, Violet 27",
          "system": "Ink Base - Nitrocellulose Polyurethane",
          "pigment": "Violet 27",
          "reference_standard": "Finalux 108",
          "conditions": "B4 Cup @26°C",
          "result": {
            "Grinding (µm)": "< 5 µm",
            "Colour Shade": "As per Std",
            "Transparency": "As per Std",
            "Color Strength (%)": "94-95",
            "Viscosity (B4 Cup @26°C)": "21 s",
            "Adhesion (Tape Test)": "Pass",
            "Gloss @ 60°": "9.1",
            "Re-solubility (Rating)": "2",
            "Separation": "No",
            "Settling": "No"
          },
          "vs_reference": {
            "Grinding (µm)": "< 5 µm",
            "Colour Shade": "Reference Std",
            "Transparency": "As per Std",
            "Color Strength (%)": "94-95 (vs 100.00)",
            "Viscosity (B4 Cup @26°C)": "21 s (vs 19 s)",
            "Adhesion (Tape Test)": "Pass",
            "Gloss @ 60°": "9.1 (vs 7.8)",
            "Re-solubility (Rating)": "2 (vs 4)",
            "Separation": "No",
            "Settling": "No"
          },
          "verdict": "not ok",
          "failure_reason": "Gloss and Re-solubility inferior"
        }
      ],
      "sample_id": "unspecified sample"
    }
  ],
  "outcome": {
    "status": "not ok",
    "basis": "Results: Not OK (Gloss and Re-solubility inferior).",
    "citation": "S 9076 #65 not ok.docx, test report table"
  }
}