← Back batch 96 of 100 ← Batch 65 Batch 68 →
Experiments / Batch 66

Batch 66 not OK

04.05.2026 (Issued on); 05.05.2026 (Completed on) · Completed By: Mr. Mohan Yadav; Authorized By: Dr. Sachin Jagtap · also written as S 9076 · S 9076 #66 · 66 · BYK 9076 · Finalux 108
Application test
not OK
2 tests
Conclusion — verbatim from the source
“Results: Not OK (Gloss and Re-solubility inferior).”
[S 9076 #66 not ok.docx, page 1]
Aim

Application test of S 9076 Batch 66 in Nitrocellulose Polyurethane ink base (Violet 23 and Violet 27 systems) against reference standard BYK 9076.

Raw materials
MaterialRole
S 9076-
BYK 9076-
Ink Base – Nitrocellulose Polyurethane-
Violet 23-
Violet 27-
Finalux 108-
Reaction conditions (optimized)
other: Rating scale: 1 – Fail, 2 – Poor, 3 – Average, 4 – Good, 5 – Excellent. Re-solubility tested in Ethyl Acetate + Toluene (50:50). Viscosity measured with B4 Cup @26°C.
Sample S 9076 Batch 66
not OK Application test in Ink Base – Nitrocellulose Polyurethane, Violet 23 system (Ref Standard Finalux 108) (Violet 23)
ParameterThis sample
Grinding (µm) Ref Standard < 5 µm; Batch < 5 µm
Colour Shade Ref Standard: Reference Std; Batch: As per Std
Transparency Ref Standard: Reference Std; Batch: Opaque
Color Strength (%) Ref Standard: 100.00; Batch: 98-99
Viscosity (B4 Cup @26°C) Ref Standard: 21 s; Batch: 28 s
Adhesion (Tape Test) Ref Standard: Pass; Batch: Pass
Gloss @ 60° Ref Standard: 66.4; Batch: 58.7
Re-solubility (Rating) Ref Standard: 4; Batch: 2
Separation Ref Standard: No; Batch: No
Settling Ref Standard: No; Batch: No
vs standard: Batch inferior to Ref Standard on Transparency (Opaque vs Reference Std), Color Strength (98-99 vs 100.00), Viscosity (28 s vs 21 s), Gloss @ 60° (58.7 vs 66.4), Re-solubility (2 vs 4); Grinding, Colour Shade, Adhesion, Separation, Settling as per standard
not OK Application test in Ink Base – Nitrocellulose Polyurethane, Violet 27 system (Ref Standard Finalux 108) (Violet 27)
ParameterThis sample
Grinding (µm) Ref Standard < 5 µm; Batch < 5 µm
Colour Shade Ref Standard: Reference Std; Batch: As per Std
Transparency Ref Standard: Reference Std; Batch: As per Std
Color Strength (%) Ref Standard: 100.00; Batch: 98-99
Viscosity (B4 Cup @26°C) Ref Standard: 19 s; Batch: 22 s
Adhesion (Tape Test) Ref Standard: Pass; Batch: Pass
Gloss @ 60° Ref Standard: 7.8; Batch: 9.3
Re-solubility (Rating) Ref Standard: 4; Batch: 2
Separation Ref Standard: No; Batch: No
Settling Ref Standard: No; Batch: No
vs standard: Batch inferior to Ref Standard on Color Strength (98-99 vs 100.00), Re-solubility (2 vs 4); Viscosity (22 s vs 19 s) and Gloss @ 60° (9.3 vs 7.8) numerically differ; Grinding, Colour Shade, Transparency, Adhesion, Separation, Settling as per standard
Test report photos
S 9076 #66 not ok.docx — 2 photos
Where this record comes from
S 9076 #66 not ok.docx — application testing
Something wrong on this page? Record a correction
Your correction is permanent: it survives every re-extraction and the field can no longer be changed by the system.
Field-by-field provenance (11 fields) — for auditors
1 extraction fragments · merged 2026-08-25 · 0 human-validated fields
Fix a wrong or missing extraction side-by-side with the original: qwen-extract--S_9076_66_not_ok--S_9076_66
FieldSourceExtractorConf.
dateS 9076 #66 not ok.docx single-page test report (whole document) qwen-tasks/extract-fragment.md@unversionedhigh
scientistS 9076 #66 not ok.docx single-page test report (whole document) qwen-tasks/extract-fragment.md@unversionedhigh
aimS 9076 #66 not ok.docx single-page test report (whole document) qwen-tasks/extract-fragment.md@unversionedhigh
materials[0]S 9076 #66 not ok.docx single-page test report (whole document) qwen-tasks/extract-fragment.md@unversionedhigh
materials[1]S 9076 #66 not ok.docx single-page test report (whole document) qwen-tasks/extract-fragment.md@unversionedhigh
materials[2]S 9076 #66 not ok.docx single-page test report (whole document) qwen-tasks/extract-fragment.md@unversionedhigh
materials[3]S 9076 #66 not ok.docx single-page test report (whole document) qwen-tasks/extract-fragment.md@unversionedhigh
materials[4]S 9076 #66 not ok.docx single-page test report (whole document) qwen-tasks/extract-fragment.md@unversionedhigh
materials[5]S 9076 #66 not ok.docx single-page test report (whole document) qwen-tasks/extract-fragment.md@unversionedhigh
samples[0]S 9076 #66 not ok.docx single-page test report (whole document) qwen-tasks/extract-fragment.md@unversionedhigh
outcomeS 9076 #66 not ok.docx single-page test report (whole document) qwen-tasks/extract-fragment.md@unversionedhigh
Raw record JSON
{
  "record_id": "exp-9076-066",
  "project": "9076",
  "aliases": [
    "S 9076",
    "S 9076 #66",
    "66",
    "BYK 9076",
    "Finalux 108"
  ],
  "provenance": {
    "fragments": [
      "qwen-extract--S_9076_66_not_ok--S_9076_66"
    ],
    "field_provenance": {
      "date": {
        "source_file": "pdf/9076 Data for Raven POC project/Application tetsing Report/S 9076 #66 not ok.docx",
        "extractor": "qwen-tasks/extract-fragment.md",
        "extractor_version": "unversioned",
        "extracted_date": "",
        "locator": "single-page test report (whole document)",
        "human_checked": true
      },
      "scientist": {
        "source_file": "pdf/9076 Data for Raven POC project/Application tetsing Report/S 9076 #66 not ok.docx",
        "extractor": "qwen-tasks/extract-fragment.md",
        "extractor_version": "unversioned",
        "extracted_date": "",
        "locator": "single-page test report (whole document)",
        "human_checked": true
      },
      "aim": {
        "source_file": "pdf/9076 Data for Raven POC project/Application tetsing Report/S 9076 #66 not ok.docx",
        "extractor": "qwen-tasks/extract-fragment.md",
        "extractor_version": "unversioned",
        "extracted_date": "",
        "locator": "single-page test report (whole document)",
        "human_checked": true
      },
      "materials[0]": {
        "source_file": "pdf/9076 Data for Raven POC project/Application tetsing Report/S 9076 #66 not ok.docx",
        "extractor": "qwen-tasks/extract-fragment.md",
        "extractor_version": "unversioned",
        "extracted_date": "",
        "locator": "single-page test report (whole document)",
        "confidence": "high",
        "human_checked": true
      },
      "materials[1]": {
        "source_file": "pdf/9076 Data for Raven POC project/Application tetsing Report/S 9076 #66 not ok.docx",
        "extractor": "qwen-tasks/extract-fragment.md",
        "extractor_version": "unversioned",
        "extracted_date": "",
        "locator": "single-page test report (whole document)",
        "confidence": "high",
        "human_checked": true
      },
      "materials[2]": {
        "source_file": "pdf/9076 Data for Raven POC project/Application tetsing Report/S 9076 #66 not ok.docx",
        "extractor": "qwen-tasks/extract-fragment.md",
        "extractor_version": "unversioned",
        "extracted_date": "",
        "locator": "single-page test report (whole document)",
        "confidence": "high",
        "human_checked": true
      },
      "materials[3]": {
        "source_file": "pdf/9076 Data for Raven POC project/Application tetsing Report/S 9076 #66 not ok.docx",
        "extractor": "qwen-tasks/extract-fragment.md",
        "extractor_version": "unversioned",
        "extracted_date": "",
        "locator": "single-page test report (whole document)",
        "confidence": "high",
        "human_checked": true
      },
      "materials[4]": {
        "source_file": "pdf/9076 Data for Raven POC project/Application tetsing Report/S 9076 #66 not ok.docx",
        "extractor": "qwen-tasks/extract-fragment.md",
        "extractor_version": "unversioned",
        "extracted_date": "",
        "locator": "single-page test report (whole document)",
        "confidence": "high",
        "human_checked": true
      },
      "materials[5]": {
        "source_file": "pdf/9076 Data for Raven POC project/Application tetsing Report/S 9076 #66 not ok.docx",
        "extractor": "qwen-tasks/extract-fragment.md",
        "extractor_version": "unversioned",
        "extracted_date": "",
        "locator": "single-page test report (whole document)",
        "confidence": "high",
        "human_checked": true
      },
      "samples[0]": {
        "source_file": "pdf/9076 Data for Raven POC project/Application tetsing Report/S 9076 #66 not ok.docx",
        "extractor": "qwen-tasks/extract-fragment.md",
        "extractor_version": "unversioned",
        "extracted_date": "",
        "locator": "single-page test report (whole document)",
        "human_checked": true
      },
      "outcome": {
        "source_file": "pdf/9076 Data for Raven POC project/Application tetsing Report/S 9076 #66 not ok.docx",
        "extractor": "qwen-tasks/extract-fragment.md",
        "extractor_version": "unversioned",
        "extracted_date": "",
        "locator": "single-page test report (whole document)",
        "human_checked": true
      }
    },
    "last_merged": "2026-08-25"
  },
  "documents": [
    {
      "file": "pdf/9076 Data for Raven POC project/Application tetsing Report/S 9076 #66 not ok.docx",
      "role": "application_test",
      "link_basis": "alias match: S 9076",
      "link_status": "rule"
    }
  ],
  "validation": {
    "validated_fields": {},
    "corrections_applied": []
  },
  "date": "04.05.2026 (Issued on); 05.05.2026 (Completed on)",
  "scientist": "Completed By: Mr. Mohan Yadav; Authorized By: Dr. Sachin Jagtap",
  "aim": "Application test of S 9076 Batch 66 in Nitrocellulose Polyurethane ink base (Violet 23 and Violet 27 systems) against reference standard BYK 9076.",
  "conditions": {
    "other": "Rating scale: 1 – Fail, 2 – Poor, 3 – Average, 4 – Good, 5 – Excellent. Re-solubility tested in Ethyl Acetate + Toluene (50:50). Viscosity measured with B4 Cup @26°C."
  },
  "materials": [
    {
      "name": "S 9076",
      "role": "unknown",
      "notes": "Batch No 66; Nature of Sample: Liquid; Colour: Amber",
      "role_verbatim": "sample under test"
    },
    {
      "name": "BYK 9076",
      "role": "unknown",
      "notes": "Nature: Liquid; Colour: Amber",
      "role_verbatim": "reference standard"
    },
    {
      "name": "Ink Base – Nitrocellulose Polyurethane",
      "role": "unknown",
      "role_verbatim": "test system / ink base"
    },
    {
      "name": "Violet 23",
      "role": "unknown",
      "role_verbatim": "pigment / colorant in test system"
    },
    {
      "name": "Violet 27",
      "role": "unknown",
      "role_verbatim": "pigment / colorant in test system"
    },
    {
      "name": "Finalux 108",
      "role": "unknown",
      "role_verbatim": "reference standard for both Violet 23 and Violet 27 systems"
    }
  ],
  "samples": [
    {
      "sample_id": "S 9076 Batch 66",
      "name": "S 9076",
      "batch": "66",
      "application_tests": [
        {
          "test": "Application test in Ink Base – Nitrocellulose Polyurethane, Violet 23 system (Ref Standard Finalux 108)",
          "system": "Violet 23",
          "conditions": "vs Ref Standard Finalux 108",
          "result": {
            "Grinding (µm)": "Ref Standard < 5 µm; Batch < 5 µm",
            "Colour Shade": "Ref Standard: Reference Std; Batch: As per Std",
            "Transparency": "Ref Standard: Reference Std; Batch: Opaque",
            "Color Strength (%)": "Ref Standard: 100.00; Batch: 98-99",
            "Viscosity (B4 Cup @26°C)": "Ref Standard: 21 s; Batch: 28 s",
            "Adhesion (Tape Test)": "Ref Standard: Pass; Batch: Pass",
            "Gloss @ 60°": "Ref Standard: 66.4; Batch: 58.7",
            "Re-solubility (Rating)": "Ref Standard: 4; Batch: 2",
            "Separation": "Ref Standard: No; Batch: No",
            "Settling": "Ref Standard: No; Batch: No"
          },
          "vs_reference": "Batch inferior to Ref Standard on Transparency (Opaque vs Reference Std), Color Strength (98-99 vs 100.00), Viscosity (28 s vs 21 s), Gloss @ 60° (58.7 vs 66.4), Re-solubility (2 vs 4); Grinding, Colour Shade, Adhesion, Separation, Settling as per standard",
          "verdict": "not ok"
        },
        {
          "test": "Application test in Ink Base – Nitrocellulose Polyurethane, Violet 27 system (Ref Standard Finalux 108)",
          "system": "Violet 27",
          "conditions": "vs Ref Standard Finalux 108",
          "result": {
            "Grinding (µm)": "Ref Standard < 5 µm; Batch < 5 µm",
            "Colour Shade": "Ref Standard: Reference Std; Batch: As per Std",
            "Transparency": "Ref Standard: Reference Std; Batch: As per Std",
            "Color Strength (%)": "Ref Standard: 100.00; Batch: 98-99",
            "Viscosity (B4 Cup @26°C)": "Ref Standard: 19 s; Batch: 22 s",
            "Adhesion (Tape Test)": "Ref Standard: Pass; Batch: Pass",
            "Gloss @ 60°": "Ref Standard: 7.8; Batch: 9.3",
            "Re-solubility (Rating)": "Ref Standard: 4; Batch: 2",
            "Separation": "Ref Standard: No; Batch: No",
            "Settling": "Ref Standard: No; Batch: No"
          },
          "vs_reference": "Batch inferior to Ref Standard on Color Strength (98-99 vs 100.00), Re-solubility (2 vs 4); Viscosity (22 s vs 19 s) and Gloss @ 60° (9.3 vs 7.8) numerically differ; Grinding, Colour Shade, Transparency, Adhesion, Separation, Settling as per standard",
          "verdict": "not ok"
        }
      ],
      "notes": "Re-solubility photos for both systems are included in the report as embedded images (media/image3.jpeg, media/image2.jpeg); only the rating numbers are in the text layer."
    }
  ],
  "outcome": {
    "status": "not ok",
    "basis": "Results: Not OK (Gloss and Re-solubility inferior).",
    "citation": "[S 9076 #66 not ok.docx, page 1]"
  }
}