Experiments / Batch 66
Batch 66 not OK
04.05.2026 (Issued on); 05.05.2026 (Completed on) ·
Completed By: Mr. Mohan Yadav; Authorized By: Dr. Sachin Jagtap ·
also written as S 9076 · S 9076 #66 · 66 · BYK 9076 · Finalux 108
Application test
not OK
2 tests
Conclusion — verbatim from the source
“Results: Not OK (Gloss and Re-solubility inferior).”
[S 9076 #66 not ok.docx, page 1]
Aim
Application test of S 9076 Batch 66 in Nitrocellulose Polyurethane ink base (Violet 23 and Violet 27 systems) against reference standard BYK 9076.
Raw materials
| Material | Role |
|---|---|
| S 9076 | - |
| BYK 9076 | - |
| Ink Base – Nitrocellulose Polyurethane | - |
| Violet 23 | - |
| Violet 27 | - |
| Finalux 108 | - |
Reaction conditions (optimized)
other: Rating scale: 1 – Fail, 2 – Poor, 3 – Average, 4 – Good, 5 – Excellent. Re-solubility tested in Ethyl Acetate + Toluene (50:50). Viscosity measured with B4 Cup @26°C.
Sample S 9076 Batch 66
not OK
Application test in Ink Base – Nitrocellulose Polyurethane, Violet 23 system (Ref Standard Finalux 108) (Violet 23)
| Parameter | This sample |
|---|---|
| Grinding (µm) | Ref Standard < 5 µm; Batch < 5 µm |
| Colour Shade | Ref Standard: Reference Std; Batch: As per Std |
| Transparency | Ref Standard: Reference Std; Batch: Opaque |
| Color Strength (%) | Ref Standard: 100.00; Batch: 98-99 |
| Viscosity (B4 Cup @26°C) | Ref Standard: 21 s; Batch: 28 s |
| Adhesion (Tape Test) | Ref Standard: Pass; Batch: Pass |
| Gloss @ 60° | Ref Standard: 66.4; Batch: 58.7 |
| Re-solubility (Rating) | Ref Standard: 4; Batch: 2 |
| Separation | Ref Standard: No; Batch: No |
| Settling | Ref Standard: No; Batch: No |
vs standard: Batch inferior to Ref Standard on Transparency (Opaque vs Reference Std), Color Strength (98-99 vs 100.00), Viscosity (28 s vs 21 s), Gloss @ 60° (58.7 vs 66.4), Re-solubility (2 vs 4); Grinding, Colour Shade, Adhesion, Separation, Settling as per standard
not OK
Application test in Ink Base – Nitrocellulose Polyurethane, Violet 27 system (Ref Standard Finalux 108) (Violet 27)
| Parameter | This sample |
|---|---|
| Grinding (µm) | Ref Standard < 5 µm; Batch < 5 µm |
| Colour Shade | Ref Standard: Reference Std; Batch: As per Std |
| Transparency | Ref Standard: Reference Std; Batch: As per Std |
| Color Strength (%) | Ref Standard: 100.00; Batch: 98-99 |
| Viscosity (B4 Cup @26°C) | Ref Standard: 19 s; Batch: 22 s |
| Adhesion (Tape Test) | Ref Standard: Pass; Batch: Pass |
| Gloss @ 60° | Ref Standard: 7.8; Batch: 9.3 |
| Re-solubility (Rating) | Ref Standard: 4; Batch: 2 |
| Separation | Ref Standard: No; Batch: No |
| Settling | Ref Standard: No; Batch: No |
vs standard: Batch inferior to Ref Standard on Color Strength (98-99 vs 100.00), Re-solubility (2 vs 4); Viscosity (22 s vs 19 s) and Gloss @ 60° (9.3 vs 7.8) numerically differ; Grinding, Colour Shade, Transparency, Adhesion, Separation, Settling as per standard
Test report photos
Where this record comes from
S 9076 #66 not ok.docx
— application testing
Something wrong on this page? Record a correction
Your correction is permanent: it survives every re-extraction and the field can no longer be changed by the system.
Field-by-field provenance (11 fields) — for auditors
1 extraction fragments · merged 2026-08-25 · 0 human-validated fields
Fix a wrong or missing extraction side-by-side with the original:
qwen-extract--S_9076_66_not_ok--S_9076_66
| Field | Source | Extractor | Conf. |
|---|---|---|---|
| date | S 9076 #66 not ok.docx single-page test report (whole document) | qwen-tasks/extract-fragment.md@unversioned | high |
| scientist | S 9076 #66 not ok.docx single-page test report (whole document) | qwen-tasks/extract-fragment.md@unversioned | high |
| aim | S 9076 #66 not ok.docx single-page test report (whole document) | qwen-tasks/extract-fragment.md@unversioned | high |
| materials[0] | S 9076 #66 not ok.docx single-page test report (whole document) | qwen-tasks/extract-fragment.md@unversioned | high |
| materials[1] | S 9076 #66 not ok.docx single-page test report (whole document) | qwen-tasks/extract-fragment.md@unversioned | high |
| materials[2] | S 9076 #66 not ok.docx single-page test report (whole document) | qwen-tasks/extract-fragment.md@unversioned | high |
| materials[3] | S 9076 #66 not ok.docx single-page test report (whole document) | qwen-tasks/extract-fragment.md@unversioned | high |
| materials[4] | S 9076 #66 not ok.docx single-page test report (whole document) | qwen-tasks/extract-fragment.md@unversioned | high |
| materials[5] | S 9076 #66 not ok.docx single-page test report (whole document) | qwen-tasks/extract-fragment.md@unversioned | high |
| samples[0] | S 9076 #66 not ok.docx single-page test report (whole document) | qwen-tasks/extract-fragment.md@unversioned | high |
| outcome | S 9076 #66 not ok.docx single-page test report (whole document) | qwen-tasks/extract-fragment.md@unversioned | high |
Raw record JSON
{
"record_id": "exp-9076-066",
"project": "9076",
"aliases": [
"S 9076",
"S 9076 #66",
"66",
"BYK 9076",
"Finalux 108"
],
"provenance": {
"fragments": [
"qwen-extract--S_9076_66_not_ok--S_9076_66"
],
"field_provenance": {
"date": {
"source_file": "pdf/9076 Data for Raven POC project/Application tetsing Report/S 9076 #66 not ok.docx",
"extractor": "qwen-tasks/extract-fragment.md",
"extractor_version": "unversioned",
"extracted_date": "",
"locator": "single-page test report (whole document)",
"human_checked": true
},
"scientist": {
"source_file": "pdf/9076 Data for Raven POC project/Application tetsing Report/S 9076 #66 not ok.docx",
"extractor": "qwen-tasks/extract-fragment.md",
"extractor_version": "unversioned",
"extracted_date": "",
"locator": "single-page test report (whole document)",
"human_checked": true
},
"aim": {
"source_file": "pdf/9076 Data for Raven POC project/Application tetsing Report/S 9076 #66 not ok.docx",
"extractor": "qwen-tasks/extract-fragment.md",
"extractor_version": "unversioned",
"extracted_date": "",
"locator": "single-page test report (whole document)",
"human_checked": true
},
"materials[0]": {
"source_file": "pdf/9076 Data for Raven POC project/Application tetsing Report/S 9076 #66 not ok.docx",
"extractor": "qwen-tasks/extract-fragment.md",
"extractor_version": "unversioned",
"extracted_date": "",
"locator": "single-page test report (whole document)",
"confidence": "high",
"human_checked": true
},
"materials[1]": {
"source_file": "pdf/9076 Data for Raven POC project/Application tetsing Report/S 9076 #66 not ok.docx",
"extractor": "qwen-tasks/extract-fragment.md",
"extractor_version": "unversioned",
"extracted_date": "",
"locator": "single-page test report (whole document)",
"confidence": "high",
"human_checked": true
},
"materials[2]": {
"source_file": "pdf/9076 Data for Raven POC project/Application tetsing Report/S 9076 #66 not ok.docx",
"extractor": "qwen-tasks/extract-fragment.md",
"extractor_version": "unversioned",
"extracted_date": "",
"locator": "single-page test report (whole document)",
"confidence": "high",
"human_checked": true
},
"materials[3]": {
"source_file": "pdf/9076 Data for Raven POC project/Application tetsing Report/S 9076 #66 not ok.docx",
"extractor": "qwen-tasks/extract-fragment.md",
"extractor_version": "unversioned",
"extracted_date": "",
"locator": "single-page test report (whole document)",
"confidence": "high",
"human_checked": true
},
"materials[4]": {
"source_file": "pdf/9076 Data for Raven POC project/Application tetsing Report/S 9076 #66 not ok.docx",
"extractor": "qwen-tasks/extract-fragment.md",
"extractor_version": "unversioned",
"extracted_date": "",
"locator": "single-page test report (whole document)",
"confidence": "high",
"human_checked": true
},
"materials[5]": {
"source_file": "pdf/9076 Data for Raven POC project/Application tetsing Report/S 9076 #66 not ok.docx",
"extractor": "qwen-tasks/extract-fragment.md",
"extractor_version": "unversioned",
"extracted_date": "",
"locator": "single-page test report (whole document)",
"confidence": "high",
"human_checked": true
},
"samples[0]": {
"source_file": "pdf/9076 Data for Raven POC project/Application tetsing Report/S 9076 #66 not ok.docx",
"extractor": "qwen-tasks/extract-fragment.md",
"extractor_version": "unversioned",
"extracted_date": "",
"locator": "single-page test report (whole document)",
"human_checked": true
},
"outcome": {
"source_file": "pdf/9076 Data for Raven POC project/Application tetsing Report/S 9076 #66 not ok.docx",
"extractor": "qwen-tasks/extract-fragment.md",
"extractor_version": "unversioned",
"extracted_date": "",
"locator": "single-page test report (whole document)",
"human_checked": true
}
},
"last_merged": "2026-08-25"
},
"documents": [
{
"file": "pdf/9076 Data for Raven POC project/Application tetsing Report/S 9076 #66 not ok.docx",
"role": "application_test",
"link_basis": "alias match: S 9076",
"link_status": "rule"
}
],
"validation": {
"validated_fields": {},
"corrections_applied": []
},
"date": "04.05.2026 (Issued on); 05.05.2026 (Completed on)",
"scientist": "Completed By: Mr. Mohan Yadav; Authorized By: Dr. Sachin Jagtap",
"aim": "Application test of S 9076 Batch 66 in Nitrocellulose Polyurethane ink base (Violet 23 and Violet 27 systems) against reference standard BYK 9076.",
"conditions": {
"other": "Rating scale: 1 – Fail, 2 – Poor, 3 – Average, 4 – Good, 5 – Excellent. Re-solubility tested in Ethyl Acetate + Toluene (50:50). Viscosity measured with B4 Cup @26°C."
},
"materials": [
{
"name": "S 9076",
"role": "unknown",
"notes": "Batch No 66; Nature of Sample: Liquid; Colour: Amber",
"role_verbatim": "sample under test"
},
{
"name": "BYK 9076",
"role": "unknown",
"notes": "Nature: Liquid; Colour: Amber",
"role_verbatim": "reference standard"
},
{
"name": "Ink Base – Nitrocellulose Polyurethane",
"role": "unknown",
"role_verbatim": "test system / ink base"
},
{
"name": "Violet 23",
"role": "unknown",
"role_verbatim": "pigment / colorant in test system"
},
{
"name": "Violet 27",
"role": "unknown",
"role_verbatim": "pigment / colorant in test system"
},
{
"name": "Finalux 108",
"role": "unknown",
"role_verbatim": "reference standard for both Violet 23 and Violet 27 systems"
}
],
"samples": [
{
"sample_id": "S 9076 Batch 66",
"name": "S 9076",
"batch": "66",
"application_tests": [
{
"test": "Application test in Ink Base – Nitrocellulose Polyurethane, Violet 23 system (Ref Standard Finalux 108)",
"system": "Violet 23",
"conditions": "vs Ref Standard Finalux 108",
"result": {
"Grinding (µm)": "Ref Standard < 5 µm; Batch < 5 µm",
"Colour Shade": "Ref Standard: Reference Std; Batch: As per Std",
"Transparency": "Ref Standard: Reference Std; Batch: Opaque",
"Color Strength (%)": "Ref Standard: 100.00; Batch: 98-99",
"Viscosity (B4 Cup @26°C)": "Ref Standard: 21 s; Batch: 28 s",
"Adhesion (Tape Test)": "Ref Standard: Pass; Batch: Pass",
"Gloss @ 60°": "Ref Standard: 66.4; Batch: 58.7",
"Re-solubility (Rating)": "Ref Standard: 4; Batch: 2",
"Separation": "Ref Standard: No; Batch: No",
"Settling": "Ref Standard: No; Batch: No"
},
"vs_reference": "Batch inferior to Ref Standard on Transparency (Opaque vs Reference Std), Color Strength (98-99 vs 100.00), Viscosity (28 s vs 21 s), Gloss @ 60° (58.7 vs 66.4), Re-solubility (2 vs 4); Grinding, Colour Shade, Adhesion, Separation, Settling as per standard",
"verdict": "not ok"
},
{
"test": "Application test in Ink Base – Nitrocellulose Polyurethane, Violet 27 system (Ref Standard Finalux 108)",
"system": "Violet 27",
"conditions": "vs Ref Standard Finalux 108",
"result": {
"Grinding (µm)": "Ref Standard < 5 µm; Batch < 5 µm",
"Colour Shade": "Ref Standard: Reference Std; Batch: As per Std",
"Transparency": "Ref Standard: Reference Std; Batch: As per Std",
"Color Strength (%)": "Ref Standard: 100.00; Batch: 98-99",
"Viscosity (B4 Cup @26°C)": "Ref Standard: 19 s; Batch: 22 s",
"Adhesion (Tape Test)": "Ref Standard: Pass; Batch: Pass",
"Gloss @ 60°": "Ref Standard: 7.8; Batch: 9.3",
"Re-solubility (Rating)": "Ref Standard: 4; Batch: 2",
"Separation": "Ref Standard: No; Batch: No",
"Settling": "Ref Standard: No; Batch: No"
},
"vs_reference": "Batch inferior to Ref Standard on Color Strength (98-99 vs 100.00), Re-solubility (2 vs 4); Viscosity (22 s vs 19 s) and Gloss @ 60° (9.3 vs 7.8) numerically differ; Grinding, Colour Shade, Transparency, Adhesion, Separation, Settling as per standard",
"verdict": "not ok"
}
],
"notes": "Re-solubility photos for both systems are included in the report as embedded images (media/image3.jpeg, media/image2.jpeg); only the rating numbers are in the text layer."
}
],
"outcome": {
"status": "not ok",
"basis": "Results: Not OK (Gloss and Re-solubility inferior).",
"citation": "[S 9076 #66 not ok.docx, page 1]"
}
}