Pipeline
Turn the document drop into verified experiment records — work the steps left to right.
1
Discoversee what's in the drop
2
Extractdocuments → data, checked as you go
3
Linkconnect to experiments
4
Browsethe experiment records
Original · Lab Batch 05.pdf
open ↗Extracted values
… checked
Cited: page 1 (all tables), page 2 (Conclusion block) (highlighted). Compare with the original on the left.
Press Enter to OK the highlighted value, or click OK / fix on any value.
Experiment: exp-9076-005
✓ Every value checked — fragment marked reviewed.
All checked — go to Link →
date
high27.12.22
aim
highTo develop product equivalent to reference product
atmosphere
highnitrogen
Materials high
| # | sr_no | name | source | quantity | unit | purity_pct |
|---|---|---|---|---|---|---|
| 0 | 1 | Vicasurf -1010 | FOIL | 300 | gms | 100 |
| 1 | 2 | Phosphorous pentaoxide | FOIL | 10.5 | gms | 100 |
| 2 | 3 | Lupasol G-20 WF | FOIL | 7.5 | gms | 100 |
Process steps high
| Step | Charged | What happened | Results | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Step 1
time_hrs 1-5 temperature 40-75 temperature_unit °C pressure_vacuum_n2 Yes
|
— |
|
unlabelled 38
|
||||||||||
|
Step 2
time_hrs 1-3 temperature 40-70 temperature_unit °C pressure_vacuum_n2 Yes
|
— |
|
unlabelled 38
unlabelled 19
|
[
{
"pressure_vacuum_n2": "Yes",
"procedure": [
{
"action": "Step- A To main reactor added Vicasurf 1010 under stirring and nitrogen atmosphere temp. 40 deg increased temp slowly with addition of P- pentaoxide . Upon feed completion temp raised to 75 deg C and digested for 2-3 hrs. Appearance was yellowish with slight gripped in viscosity. Upon digestion cooled to RT.AV-38"
}
],
"results": [
{
"measurement": "AV",
"parameter": "unlabelled",
"value": "38",
"verbatim": "AV-38"
}
],
"step": 1,
"temperature": "40-75",
"temperature_unit": "\u00b0C",
"time_hrs": "1-5"
},
{
"pressure_vacuum_n2": "Yes",
"procedure": [
{
"action": "Step-B To main reactor added Step- A reaction mass under stirring and nitrogen atmosphere temp. 40 deg Started slowly addition of Lupasol G-20 WF slowly , slowly gripped in viscosity found. upon feed completion stirred well for 1-2 hrs then cooled to RT.AV-38 Amine Value- 19"
}
],
"remarks": "Yellowish flow able liquid",
"results": [
{
"measurement": "AV",
"parameter": "unlabelled",
"value": "38",
"verbatim": "AV-38"
},
{
"measurement": "Amine Value",
"parameter": "unlabelled",
"value": "19",
"verbatim": "Amine Value- 19"
}
],
"step": 2,
"temperature": "40-70",
"temperature_unit": "\u00b0C",
"time_hrs": "1-3"
}
]
observations high
['Appearance was yellowish with slight gripped in viscosity (Step-A)', 'slowly gripped in viscosity found (Step-B)', 'Yellowish flow able liquid (Step-B remarks)']
Outcome medium check against source
statusok
basisTested on different pigment found equivalent results to reference product/ Only re solubility parameters was inferior etc.
citationpdf/9076 Data for Raven POC project/Old ELN/Lab Batch 05.pdf, page 2
More actions — correct a value · link · ignore
History (1)
| Action | Field | Value | Date |
|---|---|---|---|
| verify | 2026-08-20 |
Raw fragment JSON
{
"fragment_id": "qwen-extract--lab-batch-05--lab-batch-05",
"source_file": "pdf/9076 Data for Raven POC project/Old ELN/Lab Batch 05.pdf",
"derived_from": [
"ocr/Lab Batch 05/Lab Batch 05_0.md",
"ocr/Lab Batch 05/Lab Batch 05_1_res.json"
],
"locator": "page 1 (all tables), page 2 (Conclusion block)",
"extractor": "qwen-tasks/extract-fragment.md",
"target_aliases": [
"Lab Batch 05"
],
"document_role": "eln_report",
"payload": {
"date": "27.12.22",
"aim": "To develop product equivalent to reference product",
"eln_form": {
"journal_version": "2.0",
"equipment": "Laboratory glass reactor set up with agitator / nitrogen system etc."
},
"materials": [
{
"sr_no": "1",
"name": "Vicasurf -1010",
"source": "FOIL",
"quantity": "300",
"unit": "gms",
"purity_pct": "100"
},
{
"sr_no": "2",
"name": "Phosphorous pentaoxide",
"source": "FOIL",
"quantity": "10.5",
"unit": "gms",
"purity_pct": "100"
},
{
"sr_no": "3",
"name": "Lupasol G-20 WF",
"source": "FOIL",
"quantity": "7.5",
"unit": "gms",
"purity_pct": "100"
}
],
"conditions": {
"atmosphere": "nitrogen"
},
"process_steps": [
{
"step": 1,
"time_hrs": "1-5",
"temperature": "40-75",
"temperature_unit": "°C",
"pressure_vacuum_n2": "Yes",
"procedure": [
{
"action": "Step- A To main reactor added Vicasurf 1010 under stirring and nitrogen atmosphere temp. 40 deg increased temp slowly with addition of P- pentaoxide . Upon feed completion temp raised to 75 deg C and digested for 2-3 hrs. Appearance was yellowish with slight gripped in viscosity. Upon digestion cooled to RT.AV-38"
}
],
"results": [
{
"measurement": "AV",
"value": "38",
"verbatim": "AV-38",
"parameter": "unlabelled"
}
]
},
{
"step": 2,
"time_hrs": "1-3",
"temperature": "40-70",
"temperature_unit": "°C",
"pressure_vacuum_n2": "Yes",
"procedure": [
{
"action": "Step-B To main reactor added Step- A reaction mass under stirring and nitrogen atmosphere temp. 40 deg Started slowly addition of Lupasol G-20 WF slowly , slowly gripped in viscosity found. upon feed completion stirred well for 1-2 hrs then cooled to RT.AV-38 Amine Value- 19"
}
],
"remarks": "Yellowish flow able liquid",
"results": [
{
"measurement": "AV",
"value": "38",
"verbatim": "AV-38",
"parameter": "unlabelled"
},
{
"measurement": "Amine Value",
"value": "19",
"verbatim": "Amine Value- 19",
"parameter": "unlabelled"
}
]
}
],
"critical_parameters": [
{
"s_no": "1",
"parameter": "aminev",
"reference_value": "30.1"
},
{
"s_no": "2",
"parameter": "av",
"reference_value": "43.2"
}
],
"observations": [
"Appearance was yellowish with slight gripped in viscosity (Step-A)",
"slowly gripped in viscosity found (Step-B)",
"Yellowish flow able liquid (Step-B remarks)"
],
"conclusion": "Product was Yellowish flow able liquid/ Tested on different pigment found equivalent results to reference product/ Only re solubility parameters was inferior etc.",
"outcome": {
"status": "ok",
"basis": "Tested on different pigment found equivalent results to reference product/ Only re solubility parameters was inferior etc.",
"citation": "pdf/9076 Data for Raven POC project/Old ELN/Lab Batch 05.pdf, page 2"
}
},
"field_confidence": {
"date": "high",
"aim": "high",
"eln_form": "high",
"materials": "high",
"conditions": "high",
"process_steps": "high",
"critical_parameters": "high",
"observations": "high",
"conclusion": "medium",
"outcome": "medium"
},
"notes": [
"Optimized Reaction Conditions section printed but values blank; Critical Process Parameter table has only headers, no rows.",
"Scientist field not printed on the form.",
"Conclusion block on page 2 was recovered from ocr/Lab Batch 05/Lab Batch 05_1_res.json (the markdown derivative for that page is empty); it also contains an uninterpretable leading token 'SPDu'.",
"Pages 3 and 4 produced no OCR output at all (parsing_res_list empty); if they contain handwritten entries they are not captured in this derivative.",
"Conclusion states solubility parameters were inferior to reference; outcome.status set ok on the basis of the explicit 'found equivalent results to reference product' statement."
]
}