Sample S 9076 #51A
result Violet 23 (NC-PU ink)
ParameterThis sampleStandard (BYK 9076 Standard)
Viscosity 32 sec 29 sec
Gloss 56.8 65.1
Colour Strength 1 1
Resolubility 4 4
Transparency Eq. to Std Ref as Std
APP DATA- BYK 9076 equivalent.xlsx
result Black (NC-PU ink)
ParameterThis sampleStandard (BYK 9076 Standard)
Viscosity 48 sec 46 sec
Gloss 41.6 41.3
Colour Strength 1 1
Resolubility 4 4
Transparency Eq to Std Ref as Std
APP DATA- BYK 9076 equivalent.xlsx
Where this record comes from
APP DATA- BYK 9076 equivalent.xlsx — application testing
Something wrong on this page? Record a correction
Your correction is permanent: it survives every re-extraction and the field can no longer be changed by the system.
Field-by-field provenance (1 fields) — for auditors
1 extraction fragments · merged 2026-08-25 · 0 human-validated fields
Fix a wrong or missing extraction side-by-side with the original: app-data--S 9076 #51A
FieldSourceExtractorConf.
samples[0]APP DATA- BYK 9076 equivalent.xlsx sheet BYK_9076_equivalent, rows 30-30 parse_app_data.py@unversionedhigh
Raw record JSON
{
  "record_id": "exp-9076-051A",
  "project": "9076",
  "aliases": [
    "S 9076 #51A"
  ],
  "provenance": {
    "fragments": [
      "app-data--S 9076 #51A"
    ],
    "field_provenance": {
      "samples[0]": {
        "source_file": "docs/Application data Summary/APP DATA- BYK 9076 equivalent.xlsx",
        "extractor": "parse_app_data.py",
        "extractor_version": "unversioned",
        "extracted_date": "2026-08-19",
        "locator": "sheet BYK_9076_equivalent, rows 30-30",
        "human_checked": true
      }
    },
    "last_merged": "2026-08-25"
  },
  "documents": [
    {
      "file": "docs/Application data Summary/APP DATA- BYK 9076 equivalent.xlsx",
      "role": "application_test",
      "link_basis": "alias match: S 9076 #51A",
      "link_status": "rule"
    }
  ],
  "validation": {
    "validated_fields": {},
    "corrections_applied": []
  },
  "samples": [
    {
      "sample_id": "S 9076 #51A",
      "application_tests": [
        {
          "test": "Violet 23",
          "system": "NC-PU ink",
          "conditions": "trial 17.12.2025",
          "result": "Viscosity: 32 sec; Gloss: 56.8; Colour Strength: 1; Resolubility: 4; Transparency: Eq. to Std",
          "vs_reference": "BYK 9076 Standard — Viscosity: 29 sec; Gloss: 65.1; Colour Strength: 1; Resolubility: 4; Transparency: Ref as Std",
          "file": "docs/Application data Summary/APP DATA- BYK 9076 equivalent.xlsx"
        },
        {
          "test": "Black",
          "system": "NC-PU ink",
          "conditions": "trial 17.12.2025",
          "result": "Viscosity: 48 sec; Gloss: 41.6; Colour Strength: 1; Resolubility: 4; Transparency: Eq to Std",
          "vs_reference": "BYK 9076 Standard — Viscosity: 46 sec; Gloss: 41.3; Colour Strength: 1; Resolubility: 4; Transparency: Ref as Std",
          "file": "docs/Application data Summary/APP DATA- BYK 9076 equivalent.xlsx"
        }
      ]
    }
  ]
}